Audio Frequency Function Generator 20Hz - 20KHz

type="html">This is an AF function generation covering the frequencies between 25-25,000 Hz in three bands. It has sine, square and triangular saw tooth outputs and has sufficient output to drive any amplifier and low distortion to be useful in high precision measurements.

Freq. response:... 25-25,000 Hz (three ranges A, B, C)
Range A:..25-250 Hz
Range B:..250-2500Hz
Range C:..2500-25,000 Hz
Distortion:..0.5 % (Max.)
Output voltage:..10 V pp Sine & Triangular
16 V pp Square wave
Output impedance:... 600 ohm

How it Works
The frequency generator uses an IC the TL082 which is a dual op-amp to produce the basic
waveforms. The first of the two op -amps in the IC is used as an oscillator the frequency of
which can be set by means of the potentiometer P2 and its range depends on the value of the
capacitor C3 and is selected by means of S1. The trimmer P1 is used to adjust the duty cycle
of the oscillator. The second op-amp is an integrator which converts the triangular wave form
that is produced by the oscillator to a square one. P4 is used to adjust the amplitude of the
signal. P3 is used to adjust the amplitude of the triangular waveform.

The signal from the output of the oscillator is taken to the circuit built around the two transistors to be converted from triangular to sinusoidal. The two trimmers P5 and P6 are used to adjust the shape of the positive and negative portions of the signal for the best symmetry a nd minimum distortion and P7 is the potentiometer which adjusts the output level for this waveform. As you see the circuit consists of fairly basic building blocks with independent adjustments for every one of them which makes a very versatile and easy to operate instrument. The power supply is also incorporated on the circuit board and you only have to connect 24 VAC across the rectifier bridge to make the circuit work.

Download User Manual
with schematic. Visit page.


15 Hz - 8 MHz Frequency Counter/Frequency Meter

type="html">
Here's a design for a simple, low-cost digital frequency counter meter. The frequency counter circuit is built around a member of the PIC family of microcontrollers from Arizona Microchip. In fact the most junior member of that family - the 16C54.

The features of the frequency counter :
  • operating frequency range from about 15Hz to 8MHz (sufficiently high to make the counter useful for troubleshooting digital circuits, microcontrollers etc.)
  • internal accuracy ± 1Hz
  • 4 digits of displayed accuracy (enough accuracy for most situations)
  • adaptive (no range switch)
  • input conditioning amplifier sensitive to 50mV
  • input protection
  • crystal controlled (therefore no need for calibration)
  • powered by a single 9V alkaline battery

The frequency counter / meter circuit can be divided into three main parts - the power supply, the input amplifier, and the digital circuitry.

Power Supply
The meter is intended to be portable and can be powered by a 9V alkaline battery. A voltage regulator is used to stabilise the supply rail to 5V. It is important for accuracy that the microcontroller has a good power supply and the regulator does this very well.

Input Amplifier
The input amplifier is the interface between the input signal and the PIC microcontroller, and its function is to condition the signal before it passes to the RTCC pin. It will convert any periodic signal (sine, triangular, square wave etc.) with a peak to peak amplitude of at least 50mV into a clean 5V TTL-level square wave as required by the RTCC input. The amplifier has a high input impedance to minimise its effect on the input signal.

Digital Circuitry
A standard power-on reset circuit is provided for the PIC. Components C8 and R13 hold the voltage at MCLR near zero volts until the PIC's oscillator has stabilised. Resistor R14 protects against C8 discharging through the MCLR pin, and diode D3 enables the capacitor to discharge quickly when power is removed.

Frequency Counter Component List
Resistors (all 1/4W 5% carbon film)
R1,R9 1k (brown, black, red, gold)
R2,R10,R11 470R (yellow, purple, brown, gold)
R3,R13 10k (brown, black, orange, gold)
R4 1M (brown, black, green, gold)
R5 2k2 (red, red, red, gold)
R6,R8,R15 220R (red, red, brown, gold)
R7 10R (brown, black, black, gold)
R12 560R (green, blue, brown, gold)
R14 100R (brown, black, brown, gold)
R16-R23 330R (orange, orange, brown, gold)

Capacitors (electrolytics 2.5mm spacing, others 5mm)
C1,C4,C6 100u electrolytic 16V
C2,C5,C7 220u electrolytic 16V
C3 100n miniature polyester
C8,C11 100n ceramic
C9,C10 22p ceramic

Semiconductors
TR1,TR3,TR4 BC549B npn transistor (or BC547B, 48C etc.)
TR2 BF244A or B N-channel JFET
TR5 ZTX313 npn switching transistor
D1-D3 1N4148 silicon diode
D4 BAT42 Schottky diode
REG1 LP2950 5V regulator
IC1 18-pin DIL socket + PIC16C54 HS/P microcontroller
DISPLAY1,2 0.56" dual 7-segment LED display, common cathode

Miscellaneous
X1 20MHz crystal, HC-49/U case
S1 miniature pcb vertical slide switch, SPDT
INPUT BCN pcb socket
BATTERY PP3 battery snap
4 x rubber feet

Download : source code text file  frequency counter / meter schematics PCB Foil Pattern PCB Silk Screen 


Source : http://www.apogeekits.com/counter_article.htm